Click to view article in PDF format.
Improved Techniques for Acquiring Pressure and Fluid Data in a Challenging Offshore Carbonate Environment*
K.D. Contreiras1, F. Van-Dúnem1, P. Weinheber2, A. Gisolf2, and M. Rueda2
Search and Discovery Article #40433 (2009)
Posted August 10, 2009
*Adapted from expanded abstract prepared for AAPG International Conference and Exhibition, Cape Town, South Africa, October 26-29, 2008.
1Schlumberger ([email protected] )
2Total
3ENI
The combination of low permeability, oil base mud and near saturated oils presents one of the most challenging environments for fluid sampling with formation testers. Low permeability indicates that the drawdown while sampling will be high but this is contra-indicated for oils that are close to saturation pressure. A logical response is to therefore reduce the flow rate but in wells drilled with OBM an unacceptably long clean-up time would result.
The Pinda formation in Block 2 offshore Angola presents just such a challenge. Formation mobilities are in the low double or single-digits, saturation pressure is usually within a few hundred psi of formation pressure and borehole stability indicates that the wells must be drilled with oil base mud.
In the course of several penetrations of the Pinda formation a number of attempts were made to acquire representative formation samples but were stymied due to either excessive drawdowns that corrupted the fluid or by excessive contamination levels that rendered the samples unsuitable for laboratory analysis. Clearly a more flexible solution was required.
In this paper we review the results from previous attempts in the Pinda. We show the pre-job modeling that was done to predict the required flow rates and the anticipated drawdowns. Ultimately a two-step solution was used. We first ran a high efficiency pretest-only WFT in order to quickly gather formation pressure data and mobility data. This data was then used to design the sampling string which was a combination of an inflatable dual packer with focused probe. We discuss the decision process that governed the choice of pump, displacement unit, probe and packer. We pay particular attention to the unique pump configurations that were required to effectively manage the drawdowns when using the probe and also to allow sufficient flow rate when using the dual packer.
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
uExample 1 – Focused Probe Sampling uExample 2 – Dual Packer Sampling
|
The Pinda was deposited in a shallow marine environment and is rich in carbonates and is frequently highly dolomitized. In such complex reservoirs the acquisition of quality formation tester samples is crucial to the reservoir evaluation. In this paper we wish to discuss results from previous attempts in the same area, the subsequent recommendations that were made and their implementation. This discussion is informed by the fact that these are low permeability rocks drilled with oil base mud, containing oils that are very close to saturation pressure.
The interplay between formation characteristics and
As can be seen the drawdown at the sand face is a function of the mobility (k/μ), the flow rate and the probe size. Therefore in order to minimize the drawdown and stay above the bubble point it is required to either reduce the flow rate or increase the probe size. However neither of these options is without consequence. When the flow rate is reduced we will reduce the drawdown but the resulting very low flow rates imply it will take much longer to clean up the oil base mud filtrate. Similarly, a larger probe size permits a larger flow rate for a given drawdown but also allows for less sealing area for the packer as the flowing area is increased. The sealing success rate must be balanced against the requirements for drawdown and flow rate.
The question is then posed: how to design a sampling program
that accounts for the bubble point and contamination conditions? Looking at Equation
1
we see that four variables affect the drawdown. The formation
permeability, k, and the fluid viscosity, μ, are out of our control. We
are left to manipulate the geometry of rp (probe radius) by how we interface
with the formation, and flow rate, Q by our pump design.
The inflatable dual packer uses two inflatable rubber elements
to isolate and communicate with the reservoir. The spacing between the
packer elements is adjustable however the nominal spacing is about 1.0
metre. Whereas the probes discussed earlier have a flow area that ranges
anywhere from 0.15 to about 2 square inches, the dual packer, when inflated
in an 8.5 inch borehole will isolate a flow area of about 960 square inches.
This obviously leads to a huge reduction in drawdown for a given flowrate and
mobility. We can model the performance of the probes and packers. The
results of this modeling are presented in
As can be seen the inflatable dual packer presents considerable
advantage in terms of reduced drawdown, increased flow rate or both.
However, the advantages of the dual packer do not come without
consideration. The dual packer is typically longer on station. Inflate and
deflate times are longer than the set and retract sequences for a single
probe. Additionally, when considering clean-up time, it is now necessary to
clean up a cylinder that is 1.0 metre in height as opposed to the cone of fluid
associated with a probe type of
As the above discussion shows, in lower permeability reservoirs
where there is a drawdown constraint due to saturation pressure, we will
either be forced to use a dual packer with its attendant considerations or,
if we elect to use a probe, forced to pump at very low flow rates. The low
flow rates, however, present a problem for sampling oil in a well drilled
with oil base mud: clean-up time will be very long. We can mitigate this by
using a focused probe sampling
Consider in Figure 1
a conventional
(non-focused) probe. We show in this figure a packer set against the borehole
wall (left hand side). We assume that the near wellbore fluid, in
yellow-green, is invaded filtrate and that the far field virgin fluid, in
blue, is the desired formation fluid. After the
Now consider the schematic of the focused sampling probe shown
in Figure 2. Note that there have been two significant changes to the
focused probe versus the conventional probe. Firstly, the probe has been
separated into two distinct flow areas. There is a perimeter ring around the
outside which we shall call the guard ring or guard side. In the center
there is a flow area which we shall call the sample probe or the sample side.
Secondly, there are now two separate flowlines into the
Example 1 – Focused Probe Sampling
We look first at the focused sampling station in Figure 3. Note at the beginning that hydrostatic pressure is ~x600 psi. Two 10 cc pretests are executed and formation pressure is x340 psi. Note that on the first pretest mobility was calculated at 13 mD/cp and on the second pretest mobility was 21 mD/cp. During the pretest and during the initial pumping sequences the inner bypass valve is open, connecting guard with sample. The sample and guard side pressure are hence reading the same. At 1000 s the lower pumpout on the guard side is activated.
At point ‘B’ at about 2900 s the lower pumpout module is stopped and the upper pumpout is started. The flow rate achieved is a very low 1.1 cc/s and the resultant drawdown is only 80 psi. Note that the inner bypass is still open so guard and sample are still reading the same pressure. This 80 psi translates to a flowing mobility of about 21 mD/cp. At about 7400 s the inner bypass is closed and both pumps are activated. This is the “split flow” mode. Initially the guard side pump is started at 2.3 cc/s and the sample side pump is started at 1 cc/s. Note immediately that the pressure on the sample side starts to fall as drawdown increases. It is interpreted that this is likely due to an increase in sample side viscosity as the lower viscosity filtrate is directed to the guard side and the higher viscosity reservoir oil heads towards the sample side. Eventually the pressure on the sample side falls lower than on the guard side (sample side drawdown is higher). As described earlier this is an undesirable situation. Best results are obtained when the drawdown on the guard exceeds the drawdown on the sample so as to encourage the separation of filtrate from reservoir oil. Therefore at about 9400 s the engineer begins stepped increases in the guard side pump speed in order to increase the guard drawdown. By ~7500 s this is achieved and sampling can commence.
Example 2 – Dual Packer Sampling
Multiple attempts to acquire a water sample in the lower part of the reservoir with a probe only resulted in high drawdown low mobility pretests. It was therefore decided to inflate the dual packer. Figure 4 shows the sequence. At point ‘A’ we see the lower pump being used to inflate the packer. During all of time period ‘A’ we are in pump-in mode to inflate the packers. At point ‘B’ we switch to pump-out mode and begin the drawdown from the formation. After initially running the lower pump at ~450 rpm the pump is slowed to 300 rpm and the flowing pressure stabilizes. The stable Δp is about 700 psi below formation pressure and the flow rate is about 1.8 cc/s. This corresponds to a mobility of about 0.2 mD/cp. At point ‘C’ the lower pump is turned off and the upper pump is started. Recall that the upper pump is configured with an extra High Pressure displacement unit (the same as the lower pump) but with a fixed displacement hydraulic pump set at about 0.3 cc/rev. As a result even a relatively high pump speed of 650 rpm results in only a 1.5 cc/s flow rate and slightly less Δp. The points marked with ‘X’ indicate where the sample bottles are filled. All of the samples obtained were less than 5% OBM filtrate (by volume).
Sampling near saturated oils from low permeability reservoirs in
a well drilled with oil base mud can provide a significant challenge for a
wireline formation tester. The conflicting requirements of drawdown and rate
will pull
Of course it is acknowledged that there is a lower limit to
permeabilities that may be sampled with the probe type tools. To that end an
inflatable dual packer is also included in the
Akurt R., et al; 2006, Focusing on Downhole Fluid Sampling and Analysis, Schlumberger Oilfield Review: Winter 2006, p. 4-19.
Beaiji, T, M. Zeybek, R. Crowell, R. Akkurt, S. Al-Dossari, A. Amin, and S. Crary; 2007, Advanced Formation Testing in OBM Using Focused Fluid Sampling for Producibility Evaluation in Mature Fields: SPE 110511 presented at the 2007 ATCE, Anaheim, California, USA, 11-14 November 2007.
Dong, C., C. Del Campo, R. Vasques, P. Hegeman, and N. Matsumoto, 2005, Formation Testing Innovations for Fluid Sampling: Seventeenth Annual Deep Offshore Technology Conference, Vitoria, Brazil, 8–10 November 2005.
Hammond, P.S., 1991, One- and Two-Phase Flow During Fluid
Sampling by a Wireline
Contreiras, K.K., F. Van-Dúnem, P. Weinheber, A. Gisolf, and M. Rueda; 2008, Improved Techniques for Acquiring Pressure and Fluid Data in a Challenging Offshore Carbonate Environment: SPE 115504, SPE ATCE in Denver, CO., 21-24 September, 2008.
Moran, J.H., and E.E. Finklea, 1962, Theoretical Analysis of Pressure Phenomena Associated with the Wireline Formation Tester: SPE Journal of Petroleum Technology, August 1962; SPE 00177.
O'Keefe, M., K.O. Eriksen, S. Williams, D. Stensland, and R. Vasques; 2006, Focused Sampling of Reservoir Fluids Achieves Undetectable Levels of Contamination: SPE paper 101084, SPE APOGC, Adelaide, Australia, 11–13 September 2006.
Schlumberger Educational Services Fundamentals of Formation Testing 2006.
Weinheber, P.J. and R. Vasques, 2006, New Formation Tester Probe Design for Low-Contamination Sampling: Paper RR presented SPWLA Annual Symposium, Veracruz, Mexico, June 4-7, 2006.
Weinheber, P.J., A. Gisolf, R.J. Jackson, and I. De Santo, 2008, Optimizing Hardware Options for Maximum Flexibility and Improved Success in Wireline Formation Testing, Sampling and Downhole Fluid Analysis Operations: SPE 19713 presented SPE 2008 NAICE, Abuja, Nigeria, 4-6 August 2008.
|